Thermoplastic elastomer(TPE) insulated and sheathed flexible control cable 450/750V are mainly used for power, lighting, electrical installations, etc

Application

TPE control cables are mainly used for AC rated voltage 450/750V and below, power, lighting, electrical installations, instrumentation, telecommunications equipment environmental requirements in place of fixed wiring and similar fixed cables. And has a lightweight, soft, waterproof, and good features, more suitable for a complex work environment, and easy to install and lay.

Executive Standard

Q/WHY72

Service Property

1. The rated voltage U0/U of the cable should be 450/750V.
2. Maximum allowed operating temperature of cable conductor should be 90℃.
3. Recommended allowable bending radius: For non-armored cable should be not less than 6 times outer diameter of the cable; For armored or copper tape shielded structure cable should be not less than 8 times outer diameter of the cable.

Type & Description

Type Description
KSS Copper core elastomer insulated and sheathed control cable
KSSP Copper core elastomer insulated copper wire braided shielded elastomer sheathed control cable
KSSP2 Copper core elastomer insulated copper tape wrapped shielded elastomer sheathed control cable
KSSP3 Copper core elastomer insulated aluminum polyester composite film wrapped shielded elastomer sheathed control cable
KSS24 Copper core elastomer insulated steel tape armored elastomer sheathed control cable
KSSP24 Copper core elastomer insulated copper wire braided shielded steel tape armored elastomer sheathed control cable
KSSP2-24 Copper core elastomer insulated copper tape wrapped shielded steel tape armored elastomer sheathed control cable
KSS34 Copper core elastomer insulated steel wire armored elastomer sheathed control cable
KSSR Copper core elastomer insulated and sheathed flexible control cable
KSSRP Copper core elastomer insulated copper wire braided shielded elastomer sheathed flexible control cable
KSUR Copper core elastomer insulated and sheathed flexible control cable
KSURP Copper core elastomer insulated copper wire braided shielded and sheathed flexible control cable

Code & Meaning

Item Code Description
Series coding K Control cable
Burning characteristic Z(A/B/C) Flame retardant grade (A/B/C)
N Fire resistant
Conductor Class 1 and 2 copper conductor
R Class 5 copper conductor
Insulation S Elastomer insulation
Sheath or inner sheath S Elastomer Sheath
U TPU sheath
Shield P Copper wire braided shield
P2 Copper tape wrapped shield
P3 Alminum polyester composite film wrapped shielded
Armor 2 Steel tape armor
3 Steel wire armor
Outer sheath 4 Elastomer sheath

Cable specification & structural parameter

Type Nominal cross section area of conductor mm²
0.75 1.0 1.5 2.5 4 6 10
Number of cores
KSS KSSP 2~61 2~14 2~10
KSSP2 KSSP3 4~61 4~14 4~10
KSS24 KSSP24 7~61 4~61 4~14 4~10
KSSP2-24 7~61 4~61 4~14 4~10
KSS34 19~61 7~61 4~14 4~10

Main technical index

1. Conductor D.C. resistance at 20℃ complies with stipulations of GB/T 3956.
2. Insulation resistance at 20℃ should be not less than 50MΩ.km.
3. Finished Cable withstand AC 3.0kV for 5 minutes without puncture.