Silicon rubber Insulated Movable Flat cable
Silicon rubber Insulated Movable Flat cable
Application
The cable employs silicon rubber as the insulation andsheath material. The silicon rubber can endure high tem-perature and wear and is flexible and corrosion-resistentIt is stable in electrical properties and resistent to agingand thus has a long service life. lt is applicalbe to the movable equipment(upto and including 8.7/15kv),eg.pallet car or deliverymachine, as the power supply cable, control, lighting andcommuni-cation cable. lt has found its use in metal refiningelectrical, ship or port industries etc,
Manufacturing standard
Q/WHY10
Service characteristics1
1,Rated voltage: UO/U 450/750V,0.6/1kV,3.6/6KV,6/6(10)KV,8.7/10(15)kV
Max working temperature: 180℃
Min environment temperature: -60℃(fixed laying)
2.laying temperature:>-25℃
Type and Description
Type | Description |
YGGB YGCB | Copper core silicon rubber insulated and sheathed movable flexible flat cable |
YGVFB | Copper core silicon rubber insulated NBR sheathed movable flexible fat cable |
YGSB | Copper core silicon rubber insulated thermoplastic elastomer sheathed movable flexible flat cables |
YGGPB YGCPB | Copper core silicon rubber insulated and sheathed copper wire braided shielded movable flexible fat cable |
YGVFPB | Copper core silicon rubber insulated copper wire braided shielded NBR sheathed movable fiexible fat cable |
YGSPB | Copper core silicon rubber insulated copper wire braided shielded thermoplastic elastomer sheathed movable flexible flat cable |
Main technical index
1. Conductor D.C, resistance at 20℃ complies with stipulations of GB/T3956
2,Insulation resistance at 20℃ shouldbe not less than 500MΩ .km.
3. Cable withstand power frequency test for 5 minutes without puncture.
Rated Voltage(kv) | Power frequency test voltage kV |
0.45/0.75 | 3.0 |
0.6/1kv | 3.5 |
3.6/6 | 12.5 |
6/6 ,6/10kv | 21 |
8.7/10,8.7/15kv | 30.5 |