Rubber Insulated Flexible Cable of Rated Voltage upto and including 450/750V for General Purpose
Rubber Insulated Flexible Cable of Rated Voltage upto and including 450/750V for General Purpose
Application
This product applies for home appliances electric tools and other various movable electrical equipments of rated voltages up to andincluding 450/750V
Executive standard
GB/T 5013,JB/T 8735-2016,Q/WHY07 , IEC60245
Service property
1. Maximum long-term allowed operating temperature of cable conductor should be 60℃2. The rated voltage of the cable(wire) should be 500V, 1000V.
3. Allowed bending radius when laying should be not less than 4 times outer diameter ofthe cable.
Type and Description
Type | Description |
60245IEC53(YZ) | Ordinary rubber sheathed cable |
60245IEC57(YZW) | Ordinary polychloroprene or other equivalent synthetic elastomer sheathed cable |
60245IEC66(YCW) | Heavy polychloroprene or other equivalent synthetic elastomer sheathed fexible cable |
60245IEC81(YH) 60245IEC82(YHF) |
Rubber sheathed arc-welding electrode cable |
YZ YZW |
Tough rubber insulated common fiexible cable |
YC YCW |
Tough rubber insulated Heavy fiexible cable |
Cable Specification
Type | Rated Voltage | Cores No. | Nominal Cross Section mm2 |
60245IEC53(YZ) | 300/500V | 2,3,4,5 | 0.75~2.5 |
60245IEC57(YZW) | 300/500V | 2,3,4,5 | 0.75~2.5 |
60245IEC66(YCW) | 450/750V | 1 2 3 4 5 |
1.5-400 1.0-25 1.0-95 1.0-150 1.0-25 |
60245IEC81(YH) 60245IEC82(YHF) |
– | 1 | 16~95 |
YZ YZW | 300/500V | 2,3,4,5 4 5 6 |
4-6 1.5-6 1.5-6 0.75-6 |
YC | 450/750V | 1 2 3,4,5 4(3+1) 5(3+2,4+1) |
1.5-400 1.5-95 1.0-150 2.5-150 2.5-150 |
YCW | 450/750V | 2 3 4(3+1) 5 5(3+2,4+1) |
35-95 120-150 2.5-150 35-150 2.5-150 |