BUS CABLE KNX/EIB Cable PROFIBUS PA /DP Foundation Fieldbus Type A/B Cable Control Bus Cable
BUS CABLE KNX/EIB Cable PROFIBUS PA /DP Foundation Fieldbus Type A/B Cable ControlBus Cable
Application
Standards
» BS EN 50090
» BS EN 60228
» BS EN 50290
» RoHS Directives
» IEC60332-1
Electrical Performance
Working Voltage | 150V |
Test Voltage | 4KV |
Conductor DCR |
37.0 Ω/km (Max. @ 20°C)
|
Insulation Resistance |
100 MΩhms/km (Min.)
|
Mutual Capacitance |
100 nF/Km (Max. @ 800Hz)
|
Unbalanced Capacitance |
200 pF/100m (Max.)
|
Mechanical Characteristics
Test Object | Sheath | |
Test Material | PVC | |
Before Aging | Tensile Strength (Mpa) | ≥10 |
Elongation (%) | ≥100 | |
Aging Condition (ºCXhrs) | 100×168 | |
After Aging | Tensile Strength (Mpa) | ≥70% unaged |
Elongation (%) | ≥60% unaged | |
Cold Bend (-15ºCX4hrs) | No crack | |
Impact Test (-15ºC) | No crack | |
Longitudinal Shrinkage (%) | ≤5 |
Cable Construction
Part No. | YE00819 for PVC | KNX 2x2x20AWG | YE00820 for PVC |
YE00905 for LSZH | KNX 2x2x20AWGLSZH | YE00906 for LSZH | |
1x2x20AWG | 2x2x20AWG | 4x20AWG | |
Conductor Material | Solid Oxygen Free Copper | ||
Conductor Size | 0.8mm | ||
Insulation | S-PE | ||
Identification | Red, Black | Red, Black, Yellow, White | |
Cabling | Cores Twisted into a Pair | Cores Twisted into Pairs, Pairs Laying-up | Cores Twisted into a Quad |
Screen | Aluminium/Polyester Foil | ||
Drain Wire | Tinned Copper Wire | ||
Sheath | PVC, LSZH | ||
Sheath Color | Green | ||
Cable Diameter | 5.10mm | 5.80mm | 7.50mm |
Profibus PA Bus Cable 300V Cable
Application
Construction
1. Conductor: Solid Oxygen Free Copper (Class 1)
2. Insulation: S-PE
3. Identification: Red, Green
4. Filler: Halogen Free Compound
5. Screen:
1. Aluminium/Polyester Tape
2. Tinned Copper Wire Braided (60%)
6. Sheath: PVC/LSZH
7. Sheath: Blue
» Installation Temperature: Above 0°C
» Operating Temperature: -15°C ~ 70°C
Reference Standards
»» BS EN/IEC 61158
»» BS EN 60228
»» BS EN 50290
»» RoHS Directives
»» IEC60332-1
Electrical Performance
Working Voltage | 350V |
Test Voltage | 2.5KV |
Characteristic Impedance | 100 Ω ± 10 Ω @ 1MHz |
Conductor DCR | 22.8 Ω/km (Max. @ 20°C) |
Insulation Resistance | 1000 MΩhms/km (Min.) |
Mutual Capacitance | 60 nF/Km @ 800Hz |
Part No. | No. of Cores | Conductor Construction (mm) | Insulation Thickness(mm) | Sheath(mm) | Screen(mm) | Over Diameter(mm) |
PROFIBUS PA
|
1x2x18AWG
|
1/1.0 | 1.2 | 1.0 |
AL-Foil + TC Braided
|
7.5 |
70001E
|
1x2x18AWG
|
16/0.25 | 1.2 | 1.1 |
AL-Foil + TC Braided
|
8 |
70110E
|
1x2x18AWG
|
16/0.25 | 1.2 | 1.0 |
AL-Foil + TC Braided
|
7.8 |
PROFIBUS DP Cable
Application
For deliver time-critical communication between process automation systems and distributed peripherals. This cable is usually referred as S iemens profibus.
Construction
1. Conductor: Solid Oxygen Free Copper (Class 1)
2. Insulation: S-FPE
3. Identification: Red, Green
4. Bedding: PVC
5. Screen:
1. Aluminium/Polyester Tape
2. Tinned Copper Wire Braided (60%)
6. Sheath: PVC/LSZH/PE
7. Sheath: Violet
» Installation Temperature: Above 0°C
» Operating Temperature: -15°C ~ 70°C
Reference Standards
»» BS EN/IEC 61158
»» BS EN 60228
»» BS EN 50290
»» RoHS Directives
»» IEC60332-1
Electrical Performance
Working Voltage | 350V |
Test Voltage | 1.5KV |
Characteristic Impedance | 150 Ω ± 15 Ω @ 1MHz |
Conductor DCR | 57.1 Ω/km (Max. @ 20°C) |
Insulation Resistance | 1000 MΩhms/km (Min.) |
Mutual Capacitance | 30 nF/Km @ 800Hz |
Part No. | No. of Cores | Conductor Construction (mm) | Insulation Thickness(mm) | Sheath(mm) | Screen(mm) | Over Diameter(mm) |
3079A
|
1x2x22AWG
|
1/0.64 | 0.9 | 1.0 |
AL-Foil + TC Braided
|
8.0 |
3079ANH
|
1x2x22AWG
|
1/0.64 | 0.9 | 1.1 |
AL-Foil + TC Braided
|
8.0 |
3079E
|
1x2x22AWG
|
7/0.25 | 0.9 | 1.0 |
AL-Foil + TC Braided
|
8.0 |
70101E | 1x2x22AWG | 1/0.64 | 0.9 | 1.0 | AL-Foil + TC Braided | 8.0 |
70101NH | 1x2x22AWG | 1/0.64 | 0.9 | 1.0 | AL-Foil + TC Braided | 8.0 |
70102E | 1x2x22AWG | 7/0.25 | 0.9 | 1.0 | AL-Foil + TC Braided | 8.0 |
70103E | 1x2x22AWG | 1/0.64 | 0.9 | 1.0 | AL-Foil + TC Braided | 8.4 |
Foundation Fieldbus Type A Cable 18~14 AWG Yellow Color Control Automation Industry Cable
Application
Standards
Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC
Minimum Bending Radius: 8 x overall diameter
Electrical Perfromance
Working Voltage | 300V | |||||
Characteristic Impedance | 150 Ω ± 15 Ω @ 1MHz | |||||
Test Voltage
|
1.5KV | |||||
Conductor DCR |
21.5 Ω/km (Max. @ 20°C) for 18AWG
13.8 Ω/km (Max. @ 20°C) for 16AWG
8.2 Ω/km (Max. @ 20°C) for 14AWG
|
|||||
Insulation Resistance | 1000 MΩhms/km (Min.) | |||||
Mutual Capacitance | 79 nF/m | |||||
Velocity of Propagation | 66% |
Product Parameters
Part No. | No. of Cores | Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) | Overall Diameter (mm) |
3076F | 1x2x18AWG | 19/0.25 | 0.5 | 0.8 | AL-Foil | 6.3 |
1327A | 2x2x18AWG | 19/0.25 | 0.5 | 1.0 | AL-Foil | 11.2 |
1328A | 5x2x22AWG | 19/0.25 | 0.5 | 1.2 | AL-Foil | 13.7 |
1360A | 1x2x16AWG | 30/0.25 | 0.9 | 1.0 | AL-Foil | 9.0 |
1361A | 2x2x16AWG | 30/0.25 | 0.9 | 1.2 | AL-Foil | 14.7 |
1334A | 1x2x16AWG | 19/0.25 | 0.5 | 1.0 | AL-Foil + TC Braided | 7.3 |
1335A | 1x2x16AWG | 30/0.25 | 0.9 | 1.0 | AL-Foil + TC Braided | 9.8 |
1336A | 1x2x14AWG | 49/0.25 | 1.0 | 1.0 | AL-Foil + TC Braided | 10.9 |
Foundation Fieldbus Type A Cable 2 Cores Purple Color Automation Industry Control Cable
Application
Construction
» Installation Temperature: Above 0°C
Standards
Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC
Minimum Bending Radius: 8 x overall diameter
Electrical Perfromance
Working Voltage | 300V | |||||
Characteristic Impedance |
150 Ω ± 10 Ω 3~20MHz
|
|||||
Conductor DCR |
57.1 Ω/km (Max. @ 20°C)
|
|||||
Insulation Resistance | 1000 MΩhms/km (Min.) | |||||
Mutual Capacitance | 35 nF/Km @ 800Hz |
Product Parameters
No. of Cores | Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) | Overall Diameter (mm) |
3078F
1x2x22AWG |
7/0.25 | 0.7 | 1.0 | AL-Foil + TC Braide | 8.1 |
Control Bus Cable
Application
For data transmission to instrumentation and computer cable.
Construction
1. Conductor: Oxygen Free Copper or Tinned Copper Wire
2. Insulation: S-PE, S-FPE
3. Identification: Color Coded
4. Cabling: Twisted Pair
5. Screen:
1. Aluminium/Polyester Tape
2. Tinned Copper Wire Braided
6. Sheath: PVC/LSZH
(Note: Armor by Gavanized Steel Wire or Steel Tape is under request.)
Standards
BS EN 60228
BS EN 50290
RoHS Directives
IEC60332-1
Installation Instructions
Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC
Minimum Bending Radius: 8 x overall diameter
Product Parameters
Part No. | Conductor | Insulation Material | Screen (mm) | Sheath | |
Material | Size | ||||
9207 | TC | 1x20AWG | S-PE | AL-Foil + TC Braided | PVC |
BC | 1x20AWG | ||||
9207NH | TC | 1x20AWG | S-PE | AL-Foil + TC Braided | LSZH |
BC | 1x20AWG | ||||
9250 | BC | 1x18AWG | S-PE | Double Braid | PVC |
BC | 1x18AWG | ||||
9271 | TC | 1x2x24AWG | S-PE | Al-foil | PVC |
9272 | TC | 1x2x20AWG | S-PE | Braid | PVC |
9463 | TC | 1x2x20AWG | S-PE | AL-Foil + TC Braided | PVC |
9463DB | TC | 1x2x20AWG | S-PE | AL-Foil + TC Braided | PE |
9463NH | TC | 1x2x20AWG | S-PE | AL-Foil + TC Braided | LSZH |
9182 | TC | 1x2x22AWG | S-FPE | Al-foil | PVC |
9182NH | TC | 1x2x22AWG | S-FPE | Al-foil | LSZH |
9860 | BC | 1x2x16AWG | S-FPE | AL-Foil + TC Braided | PVC |